ADSL/GSM/GPRS telephone transmitter SH512AX
SH512AX ADSL/GSM/GPRS telephone transmitter SH512AX e-Nova Daitem
The SH512AX telephone transmitter module remotely reports all events occurring at the protected site to a remote monitoring company or the end user via the ADSL/GSM/GPRS network. It is automatically remote from the control panel, with a built-in control and programming keypad.
Any questions? Need a price? A quote? A discount on the Daitem range? Email us at info@alarme78.com, reduced VAT rate of 10% possible.
SH512AX ADSL/GSM/GPRS telephone transmitter for Daitem wireless alarms 
5-year warranty, 5-year battery life under normal use.
The SH512AX ADSL/GSM/GPRS telephone transmitter is only compatible with the Daitem e-Nova range.
ADSL/GSM/GPRS telephone transmitter module SH512AX
Transmission of the following events, whatever the medium used: Simple or confirmed intrusion, deterrence and pre-alarm (configurable), emergency call, tamper protection against opening or removal of a system component, silent alert, fire detection, domestic damage detection, low battery on a component of the alarm system, system arming/disarming (configurable), mains failure on the telephone transmitter, loss of ADSL network.
Transmission of events and captured images: Whatever the medium, alarm and fault events generate a digital message sent to the monitoring centre; via the GSM network, alarm and fault events generate a voice message sent directly to landline or mobile numbers; via the GPRS/ADSL network, the image sequences captured by an image-capture detector following an intrusion generate either a 10s video sent to the monitoring centre or images sent directly by email and available on the secure Daitem Services Protection Directe web portal; via the GSM network, the image sequences captured by an image-capture detector following an intrusion generate an MMS image sent to the end user's GSM mobile phone.
Point-to- point detector management: for priority intrusion, fire and alert messages, each detector is clearly identified by its number.
External GSM/GPRS antenna RXA03X (supplied): must be installed when the control panel is mains-powered; in battery-powered standalone mode it is only recommended to improve transmission performance.
Speaker and microphone built into the control panel: Listen-in and intercom function during the call-back period, talk-back function during the listen-in period.
Back-up function: ADSL connection with GPRS backup.
Call numbers: 3 call cycles of up to 8 numbers, repeated up to 5 times until acknowledgement, choice of the type of events to transmit per call cycle, independent acknowledgement per call cycle.
Remote commands: If GSM media are used, remote commands to arm or disarm the alarm system, control the sirens and operate the command receivers; if GSM is used, the remote commands sent outside the call-back period are only possible if the control panel-transmitter is mains-powered.
3 operating modes: Installation mode, reserved for the installer and accessed with a specific code, test mode, reserved for the main user to carry out tests without triggering the sirens, accessed with the master code, and user mode, which allows the wireless alarm system to be used without any risk of deprogramming the master code.
Tamper protection: The transmitter has mechanical tamper protection against opening and removal, as well as protection against radio jamming.
Light signalling: Three-colour indicator light to assist with programming, blue light strip signalling each command of the alarm system (arm, disarm, system status query) and each change of mode: test, user, installation.
Specifications:
- TWINBAND radio transmitter receiver
- Built-in ADSL/GSM/GPRS media
- Built-in control and programming keypad
- Three-colour programming aid indicator light
- Programmable listen-in and voice challenge function (except GPRS medium)
- Viewcom IP protocols over ADSL
- Contact ID protocol over GSM
- 3 call cycles of 2 or 3 telephone numbers or IP addresses (up to 5 call attempts per number if not acknowledged)
- Built-in voice synthesis, 6 languages
- Programmable cyclic call (start and interval from 1 minute to 31 days)
- 10s 320x240 colour alarm video sent to the monitoring centre
- Format of the image sent by MMS: 320x240 colour
- Technical faults occurring during the night reported at 8:00 am
- Protection ratings IP31 /IK04
- Powered by TWINPOWER lithium battery 2x (3.6V-13Ah) Batli22
- Operating temperature -10°C to +55°C
- Dimensions (WxHxD) 232x232x677 mm
- Weight 1.200kg (without battery)
- Indoor use
- Autonomy when calling a monitoring centre: 4 years, for 1 cyclic call/day, 5 events per year, 5 alarm video transmissions/year
- Autonomy when calling private numbers: 5 years, 10 events/year, 10 transmissions/year, 4 weekly transmissions of arming/disarming, 6 days out of 7 (SMS messages only)
Supplied with RXU03X secondary power supply by 3.7V 1.2Ah lithium battery.
Supplied without mains power supply RXU01X, RJ45/RJ45 Ethernet network cable 830-99X, RJ11/T-adapter connection lead 851-99X, RJ11/RJ45 telephone connection lead 853-99X.
Warning!!! for an ADSL connection, the main Batli22 battery must be replaced by the mains power supply RXU01X
How do I choose the right VAT rate for my alarm?
Choose the reduced 10% VAT rate if the property where the installation will take place is more than two years old; choose 20% if the installation will be carried out in a home less than two years old.
If you are unsure which VAT rate to choose, feel free to contact us by email.
-
ReferenceSH512AX
Comments (0)
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent